Contact
us for a FREE quotation by phone, fax or e-mail |
 |
 |
|
 |
| Quick Product
List |
 |
| |
|
|
|
|
|
 |
|
12
AMP 3-STAGE SOLAR CHARGE, DC LOAD AND AUTO LIGHTING
CONTROLLER
Trace
Engineering introduces the most advanced small system
controller available. It brings intelligent microprocessor
control and unsurpassed reliability to even the smallest
PV systems at an affordable price. The C12's field configurability
and feature packed design makes it the only small PV
controller you'll need!
Photovoltaic charge controller
-
Silent, solid state, series pulse width modulated
(PWM) charge control with 3-stages (bulk, absorb,
float).
- Field
adjustable setpoints with removable knobs to reduce
tampering (bulk range: 13.0 to 17.0 VDC)
- Electronic
short-circuit, overload, overtemperature and reverse
polarity protection improves reliability.
- Automatic
reset of overload protection system - eliminates problems
of tripped breakers and blown fuses.
- High
efficiency, "No diode" design without electronics
in the negative conductors (as per NEC code).
- Optional
plug-in /replaceable temperature compensation sensor-
ideal for sealed batteries.
- Continuous
rating of 12 amps @ 113degF /45degC and 8 amps @ 150degF
/65degC for severe environments.
- Designed
for 15 amps of PV short-circuit current (typically
about four 50 watt modules).
- Two
stage lightning and surge suppression through both
active and passive protection components.
- Equalize
mode (@ bulk+1 VDC for 2 hours) with automatic activation
every 30 days or if LVD is reached (defeatable).
DC
Load controller
-
Automatic low voltage disconnect (LVD) with adjustable
setpoint (LVD range 10.5 to 12.5 VDC).
- Automatic
low voltage reconnect (LVR) with adjustable setpoint
(LVR range 12.0 to 14.0 VDC).
- Selectable
automatic or manual reconnection of loads after low
voltage disconnect occurs .
-
Electronic short-circuit, overload, overtemperature
and reverse polarity protection improves reliability.
- Continuous
rating of 12 amps @ 113degF /45degC and 8 amps @ 150degF
/65degC for severe environments.
- Low
voltage disconnect warning system - blinks loads on-off-on
when the battery voltage is below the low voltage
disconnect setting after a two minute delay. Loads
are then disconnected after a 5 minute additional
time delay unless loads have been reduced and voltage
has risen above the low voltage disconnect setpoint.
- Manual
reset switch on bottom of enclosure allows one-time
10 minute grace period for operation of DC loads after
reset has occurred. Additional pushes have no effect
until voltage reaches the low voltage reconnect,
Automatic
lighting controller
-
Automatic control of lighting systems with nighttime
detection by using the PV array as a photocell.
- Adjustable
run duration from 2 to 8 hours or "dusk to dawn" all
night operation of lights,
- Electronic
short-circuit, overload, overtemperature and reverse
polarity protection improves reliability.
- Continuous
rating of 12 amps @ 113oF /45oC and 8 amps @ 150oF
/65oC for severe environments.
- Manual
reset switch on bottom of enclosure allows testing
of lights during daytime or after LVD has occured
Applications
-
Village Power
- Cabin/
Vacation Homes
- Outdoor
Area Lighting
-
Sign Lighting
-
Bus Shelters
-
Telecommunications
Designed to meet all published US and international
controller specifications available.
Dimensions
Size: 6.5" H x 4.3" Wx1.5" D
16. 5 cm x 11 cm x 4 cm
|
|
|
 |
|
|
|
| |
|
Contact SWPV any time
for more information, quotations or consultation |
|
 |
 |
 |
 |
 |