The SB 2500U is the the work-horse of
the American PV Inverter market. Since it's introduction
nearly
2 years ago, over 3,000 SB 2500s have been installed
nationwide. With it's flexable output voltage, of either
240 Vac or 208 Vac, the SB 2500U is ready to tackle
a wide range of applications from medium sized residental
systems to very large 3-phase industrial systems.

|
Download the: |
|
SB2500U
data sheet |
|
SB2500U Technical
description |
|
SB2500U Installation
and owners manual |
| |
Specifications |
| |
| Input Values
(240V) |
|
|
| Recommended max PV Power
* |
PPV |
2800 to 3000 Wp STC* |
| Max DC Power |
PDC,
max |
2500 Wp PTC** |
| DC Input voltage |
VDC |
250 - 600 Vdc |
| PV Voltage range, MPP |
VPV |
234V to 550V |
| Max input current |
IPV,
max |
10.4 A |
| DC Voltage ripple |
VPP |
< 10% |
| DC Disconnectors |
|
Optional external DC Disconnect/Breaker |
| Pole confusion protection |
|
Short Circuit diode |
| Ground fault protection |
IDif |
> 1000 mA |
|
| |
| Input Values
(208V) |
|
|
| Recommended max PV Power
* |
PPV |
2300 to 2500 Wp STC* |
| Max DC Power |
PDC,
max |
2200 Wp PTC** |
| Max DC Voltage |
VDC,
max |
600 Vdc |
| PV Voltage range, MPP |
VPV |
234V to 550V |
| Max input current |
IPV,
max |
10.5 A |
| DC Voltage ripple |
VPP |
< 10% |
| DC Disconnectors |
|
Optional external DC Disconnect/Breaker |
| Pole confusion protection |
|
Short Circuit diode |
| Ground fault protection |
IDif |
> 1000 mA |
|
| |
| Output Values
(240V) |
|
|
| Max AC Power |
PAC |
2500 W |
| Nominal AC Power |
PAC |
2200 W |
| Total Harmonic Distortion |
THDIAC |
< 4% (With KVgrid <
2% and PAC > 0.5 PACnom) |
| Operating Range, Grid
Voltage |
VAC |
211 V to 264 V |
| Operating Range, Grid
Frequency |
fAC |
59.3 Hz - 60.5 Hz |
| Phase Shift (Ref. Fundimental) |
cos(phi) |
0° |
|
| |
| Output Values
(208V) |
|
|
| Max AC Power |
PAC |
2200 W |
| Nominal AC Power |
PAC |
1850 W |
| Total Harmonic Distortion |
THDIAC |
< 4% (With KVgrid <
2% and PAC > 0.5 PACnom) |
| Operating Range, Grid
Voltage |
VAC |
183 V to 229 V |
| Operating Range, Grid
Frequency |
fAC |
59.3 Hz - 60.5 Hz |
| Phase Shift (Ref. Fundimental) |
cos(phi) |
0° |
|
| |
| Output Protection |
|
|
| Islanding Protection |
|
VAC; fAC in accordance
with UL 1741 |
| Ground Fault Protection |
|
IDIF; In accordance with
UL 1741 |
| AC Disconnect |
|
External AC Breaker |
| Short Circuit Protection |
|
Current Controlled |
| Overvoltage Classification |
|
III |
| Testing voltage (50 Hz) |
|
2.88 kV (1s) |
| Testing voltage for surge |
|
4 kV (serial interface
6 kV) (1.2/50 us) |
|
| |
| Efficiency |
|
|
| Peak Efficiency |
|
94.10 % (Rebate Efficiency) |
| Euro - ETA Efficiency |
|
93.20 % (Nominal Efficiency) |
|
| |
| Power Consumption |
|
|
| Internal consumption in
operation |
|
< 7 W |
| Internal consumption at
night |
|
0.25 W |
|
| |
| American Standards |
|
|
| Hardware Safety |
|
UL 1741 |
| Firmware Safely |
|
UL 1998 |
| Power Quality |
|
IEEE 519 |
| Anti-Islanding |
|
IEEE 929 |
| Surge Testing |
|
ANSI C62.41, C1 &
C3 |
| Electro-Magnetic Interference |
|
FCC Part 15 A & B |
|
| |
| European Standards |
|
|
| EMC |
|
EN 50081,T.1 & EN
50082,T.1 |
| Grid Interference |
|
EN 61000-3-2 |
| Grid Monitoring |
|
DIN VDE 126 |
| Low-Voltage regulation |
|
EN 50178 |
| CE Conformity |
|
EN 60146, Teil 1-1 |
|
| |
| Size and Weight |
|
|
| Width |
|
434 mm |
| Height |
|
295 mm |
| Depth |
|
214 mm |
| Weight |
|
ca. 30 kg |
|
| |
| Enclosure Ratings |
|
|
| DIN EN 60529 |
|
IP 65 |
| NEMA Rating |
|
NEMA 4X |
|
| |
| Ambient Conditions |
|
|
| Ambient Temperature Range |
|
-13ºF to +140ºF or -25ºC
to +60ºC |
| Relative Humidity Level |
|
0 to 100% |
|
| |