The SWCA serial communications interface adapter allows for
remote set-up, adjustment, troubleshooting and monitoring
of SW series inverters from a personal computer. Connection
to the SWCA can be via 4 conductor phone type cable or with
standard PC modems over telephone line
SWCA Includes:
- SW Communications Adapter with LED on-line
indicator.
- Serial port adapter (RJ11 phone jack to DB9
connector) for connection of the phone type cable to the
PC.
- 25 foot, 4 connector phone type cable (with
RJ11 jacks on both ends).
- 3.5" floppy disk with DOS SineWave control
panel software (SWCPS.EXE)
- Detailed instruction manual including installment,
software installation and suggested PC modem information.
Control your SW series inverter from your PC:
The SWCA allows control and monitoring of your SW series inverter
from your PC computer. All menu settings and LED indicators
are displayed on the PC computer screen. The included PC /
DOS software allows local connection to the inverter (up to
1000 feet) using a PC computer serial port and standard phone
type cable. You can also use any terminal emulation software
(such as HYPER-TERMINAL) with any PC or MAC computer to connect
and adjust the settings instead of the using the DOS software.
Remote Modem Connection: The SWCA makes remote set-up
simple and easy for end users, dealers, distributors or anyone
familiar with SW series inverters. Know what is going on,
change menu setting and optimize system performance without
a site visit! The SWCA can even be used to do simple troubleshooting
by accessing meters and error conditions from your home or
office. This feature is great for new users and allows dealers
to guide their customers through simple set-up and adjustment
problems that would usually require on-site assistance. An
ideal service option for authorized Trace installers, distributors
and dealers.
Remote connection requires a telephone line and a PC modem
for connection to the inverter. The computer you use to call the inverter also
requires a modem and a terminal emulation program such as
HYPER-TERMINAL or similar. Suggested Modem: US Robotics external
33.6 PC modem or equivalent.
Data Logging and Site History Information: Software developed
by third party vendors will allow collection and manipulation
of the data transmitted by the SWCA from the SW Series inverter.
Benefits:
- By accessing your SW Series inverter from the
office or home, you can reduce site visits and lower system operation and maintenance
costs.
- Optimize system performance and do remote troubleshooting
and adjust up to 8 inverters with a single PC and/or modem.
- Can be used to control all operating modes,
including; generator, energy management, utility
interactive, and utility back-up mode.
- Connect an SW inverter/charger to existing
home automation and control networks.
- Know what is happening with the energy system
at your summerhouse without a mid-winter visit.
Minimum System Requirements: IBM compatible computer with
at least a 386 processor and 8 meg RAM and DOS or Windows
software. Modem access is provided on a dial in basis only
and requires a modem capable of operation at 9600 baud with
auto answer capability. Connection of a PC or modem to the
SWCA may require additional cables and adapters. A terminal
emulation program is also required for use with modems.
|