| Specifications |
SW4024 |
SW4048 |
SW5548 |
| AC Input Voltage |
120 VAC |
120 VAC |
120 VAC |
| AC Input Voltage
Range |
|
All modes except sell mode
|
80-149
VAC |
80-149
VAC |
80-149
VAC |
|
Sell Mode
|
106-132
VAC |
106-132
VAC |
106-132
VAC |
| AC Input Current* |
60 amps
AC pass thru / 30 amps AC charging |
60 amps
AC pass thru / 30 amps AC charging |
60 amps
AC pass thru / 35 amps AC charging |
| Continuous Power
(@ 25° C) |
4000 VA |
4000 VA |
5500 VA |
| Efficiency (peak) |
94% |
95% |
96% |
| Output Voltage (RMS) |
120 VAC |
120 VAC |
120 VAC |
| Output Voltage Regulation |
+/- 5% |
+/- 5% |
+/- 5% |
| Frequency (Nominal +/- 0.04%
Crystal Controlled) |
60 Hz |
60 Hz |
60 Hz |
| Continuous Output (@ 25° C) |
33 amps AC |
33 amps AC |
46 amps AC |
| Surge Capability |
|
5 Sec Rating (resistive)
|
8000 watts |
8800 watts |
9500 watts |
|
1 mSec
|
110 amps AC |
110 amps AC |
110 amps AC |
|
100 mSec
|
78 amps AC
|
78 amps AC |
78 amps AC |
| Automatic Transfer Relay |
60 amps |
60 amps |
60 amps |
| DC Input Voltage (Nominal) |
24 VDC |
48 VDC |
48 VDC |
| DC Input Voltage Range |
22-33 VDC |
44-66 VDC |
44-66 VDC |
| DC Current at Rated Power |
200 amps DC |
100 amps DC |
140 amps DC |
| Short Circuit Current |
800 amps DC |
400 amps DC |
400 amps DC |
| Idle Consumption (Typical at
Full Voltage) |
< 16 watts |
< 16 watts |
< 20 watts |
| Search Mode Consumption |
< 1 watt |
< 1 watt |
< 1 watt |
| Low Battery Protection (Enabled) |
Adjustable low batery
cut out and cut in - variable time |
Adjustable low batery
cut out and cut in - variable time |
Adjustable low batery
cut out and cut in - variable time |
| Maximum Charge Rate (Adjustable) |
120 amps DC |
60 amps DC |
70 amps DC |
| Total Harmonic Distortion |
< 5% |
< 5% |
< 5% |
| Mechanical
Specifications |
| Specified Temperature Range |
|
|
|
|
Specified (will meet specified tolerances)
|
32° F to 77° F
(0° C to 25° C) |
32° F to 77° F
(0° C to 25° C) |
32° F to 77° F
(0° C to 25° C) |
|
Allowed (may not meet specified tolerances)
|
-40° F to 140° F
(-40° C to 60° C) |
-40° F to 140° F
(-40° C to 60° C) |
-40° F to 140° F
(-40° C to 60° C) |
| Non-Operating |
-67° F to 284° F
(-55° C to 140° C) |
-67° F to 284° F
(-55° C to 140° C) |
-67° F to 284° F
(-55° C to 140° C) |
| Enclosure Type |
Indoor, ventilated, steel chassis
with powdercoat finish |
Indoor, ventilated, steel chassis
with powdercoat finish |
Indoor, ventilated,
steel chassis with powdercoat finish |
| Unit Weight |
105 lb (48kg) |
105 lb (48kg) |
136 lb (63kg) |
| Shipping |
111 lb (50kg) |
111 lb (50kg) |
143 lb (65kg) |
| Inverter Dimensions |
15"H x 22.5"W x
9"D
(38cm H x 57cm W x 23cm D) |
15"H x 22.5"W x
9"D
(38cm H x 57cm W x 23cm D) |
15"H x 22.5"W x
9"D
(38cm H x 57cm W x 23cm D) |
| Shipping Dimensions |
20"H x 27"W x 15"D
(52cm H x 69cm W x 40cm D) |
20"H x 27"W x 15"D
(52cm H x 69cm W x 40cm D) |
20"H x 27"W x 15"D
(52cm H x 69cm W x 40cm D) |
| Mounting |
Wall Mount |
Wall Mount |
Wall Mount |
| Altitude |
|
|
|
|
Operating
|
15,000' (4,572 m) |
15,000' (4,572 m) |
15,000' (4,572 m) |
|
Non-Operating
|
50,000' (15,240 m) |
50,000' (15,240 m) |
50,000' (15,240 m) |
| Features
and Options |
| Forced Air Cooling |
Standard variable speed brushless
DC Fans |
| Three-stage charging |
Standard three-stage (bulk,
absorption, and float) |
| Control Panel |
Standard built-in, two line,
backlit, alphanumeric LCD with 8 LED status indicators |
| Auto Generator Control System |
Standard automatic generator
control system for two and three wire start generators |
| Auxiliary Relays |
Standard three user adjustable
voltage controlled signal relays for control of loads
or charging sources |
| Battery Temperature Sensor |
BTS - standard remote battery
temperature sensor for increased battery performance |
| Remote Control |
SWRC - optional remote control
and status indicator |
| Stacking Interface |
SWI - optional for series stacking
of two identical SW units for 120/240 VAC output
/ SWI/PAR - optional for paralleling two identical SW units
for twice the power output at 120 VAC/60 Hz |
| Conduit Box |
SWCB - optional side mount
conduit box for code-compliant DC wiring connections |
| Common
Specifications |
| Waveform |
Sinewave, 34 to 52 steps per
cycle |
| Load Sensing (Inverter Mode) |
Adjustable 0 to
over 200 watts (48 watts default) |
* Required for full pass thru and full charging.
Specifications subject to change without
notice.
|
|