- Utility interactive,
three-phase inverter, with models ranging from 5 kW
to 100 kW. Multiple inverters may be paralleled for
larger power installations.
- Designed for cost-effectiveness,
high performance, easy installation, and reliability.
- Advanced MPPT technology
maximizes PV array output (not for use with batteries).
- Revolutionary switching
technology utilizes insulated gate bi-polar transistors
(IGBT), greatly reducing power losses during the conversion
process.
- Meets all applicable
UL, IEEE, and NEC codes.
- Automatic operation
includes start-up, shut-down, self-diagnosis, and fault
detection.
Features
- Efficient design,
with over 95% peak efficiency for the inverter, and overall
efficiency including transformer losses, in excess of
93%.
- Digital Signal Processor
(DSP) based controls with self-diagnostics and LCD for
display of operating status.
- Inverter shut off
and reset toggle switch.
- Over- and under-voltage
and frequency protection, shutting down the inverter in
compliance with UL1741.
- Anti-islanding protection
- prevents back-feeding inverter-generated power to the
grid in the event of a utility outage.
- User definable power
tracking matches the inverter to the array, as well as
adjustable delay periods to customize system shut-down
sequences.
Options
- Variety of system
accessories for ease of system installation, including
combiner boxes, isolation transformers, disconnect switches,
etc.
- Graphical user interface
software for real time communication and control.
- Complete inverter
kits, incorporating all required accessories for NEC code
compliant installation, are available.
Note:
Products are listed by UL and/or ETL to UL specifications
Specifications
|
|
PV5
|
PV10
|
PV15
|
PV20
|
PV30
|
PV50
|
PV100
|
| Continuous Power Rating |
5kW |
10kW |
1
5kW |
20kW |
30kW |
50kW |
100kW |
| Nominal AC Voltage ( Three-phase,
± 10%) |
208VAC |
208VAC |
208VAC |
208VAC |
208VAC |
208VAC |
208VAC |
| Nominal AC Frequency (±
0.5 Hz) |
60Hz |
60Hz |
60Hz |
60Hz |
60Hz |
60Hz |
60Hz |
| Line Power Factor (Above
20% rated power) |
> 0.99 |
> 0.99 |
> 0.99 |
> 0.99
|
> 0.99 |
> 0.99 |
> 0.99 |
| Maximum AC Line Current |
15.4 amps AC
|
30.8 amps AC |
46.3 amps AC |
61.7 amps AC |
92.4 amps AC |
154 amps AC |
305 amps AC |
| AC Current Distortion (At
rated power) |
< 5% THD |
< 5% THD |
< 5% THD |
< 5% THD |
< 5% THD |
< 5% THD |
< 5% THD |
| Maximum Open Circuit Voltage |
600 VDC |
600 VDC |
600 VDC |
600 VDC |
600 VDC |
600 VDC |
600 VDC |
| Power Tracking Window Range |
330 to 600 VDC |
330 to 600 VDC |
330 to 600 VDC |
330 to 600 VDC |
330 to 600 VDC |
330 to 600 VDC |
330 to 600 VDC |
| Maximum DC Input Current |
15.9 amps DC |
31.9 amps DC |
47.8 amps DC |
63.8 amps DC |
95.7 amps DC |
159.5 amps DC |
300 amps DC |
| Max. Ripple Current (% of
rated current) |
< 5% |
< 5% |
< 5% |
< 5% |
< 5% |
< 5% |
< 5% |
| Peak Inverter Efficiency |
> 93%
|
> 95%
|
> 95%
|
> 95%
|
> 95% |
> 95% |
> 95% |
| Standby Tare Losses |
< 30 watts |
< 30 watts |
< 30 watts |
< 30 watts |
< 30 watts |
< 30 watts |
< 30 watts |
|

|
|
Mechanical Specifications
|
| Temperature Range (Ambient) |
-4° F to 122° F (-20° C
to 50° C)
|
| Temperature Range (Storage) |
-40° F to 122° F
(-40° C to 50° C) |
| Enclosure Environmental
Rating |
NEMA4
|
NEMA4 |
NEMA4 |
NEMA4 |
NEMA3R |
NEMA3R |
NEMA3R |
| Enclosure |
Galvaneal folded steel
enclosure
|
| Weight |
75 lb (34kg) |
115 lb (52kg) |
160 lb (73kg) |
160 lb (73kg) |
288 lb (131kg) |
310 lb (141kg) |
1000 lb (454kg) |
| Dimensions (H
x W x D) |
20" x 16" x 13" |
26" x 16" x 12" |
28" x 24" x 15" |
28" x 24" x 15" |
52" x 26" x 19" |
52" x 26" x 19" |
68" x 31" x 27" |
| 51 cm x 41 cm x 33 cm |
66 cm x 41 cm x 30 cm |
71 cm x 61 cm x 38 cm |
71 cm x 61 cm x 38 cm |
132 cm x 66 cm x 48 cm |
132 cm x 66 cm x 48 cm |
172 cm x 79 cm x 69 cm |
| Altitude |
6,600 ft (2,012 m) |
6,600 ft (2,012 m) |
6,600 ft (2,012 m) |
6,600 ft (2,012 m) |
6,600 ft (2,012 m) |
6,600 ft (2,012 m) |
6,600 ft (2,012 m) |
| Relative Humidity (non-condensing) |
0 to 95% |
0 to 95% |
0 to 95% |
0 to 95% |
0 to 95% |
0 to 95% |
0 to 95% |
| Array Configuration |
Monopole, negative grounded
or floating - Bi-polar, neutral grounded
|
|

|
|
Features and Options
|
| Cooling Method |
Standard - PV5: natural
convection cooling; PV10 - PV100: forced convection
cooling
|
| Protective Functions |
Standard wakeup voltage, wakeup
time delay, shutdown power, shutdown time delay, AC over
/ under voltage and time delays, AC over / under frequency
and time delays, ground over current, overtemperature,
AC and DC over current, DC over voltage |
| User Display |
Standard - LCD, four-line,
twenty-characters, with on/off toggle switch |
| AC Disconnect |
Optional - NEMA3R wall mount
enclosure, load break rated |
| DC Disconnect |
Optional - NEMA3R wall mount
enclosure, 600 VDC load break rated |
| Isolation Transformer |
Optional- High efficiency,
NEMA3R wall or floor mount enclosure |
| Combiner Enclosures |
Optional - 10 or 12 pole, with
or without diodes, NEMA3R wall mount enclosure |
| Communications Software |
Optional - Serial communications
and control software |
|
|
 |
|
|
|
| |
|
Contact SWPV any time
for more information, quotations or consultation |
|
 |
 |
 |
 |
 |
Copyright